The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience.
Each bed is provided with call station board consisting of Bed push confirmation light and re-set push. The patient can make call form the push switch. On receipt of call at the Digital Display Board, Confirmation Light on the Call Station will be on. This ensures that there is no problem in wiring.
The call received at Display Board can only be re-set by the attending nurse from the re-set push provided at the bed side of patient (Call Station Board). On attending the call, the confirmation light and the bed number at the monitor will be switched off.
If any call remains pending over a set period the particular number will be hi-lighted by Flushing the digit & buzzer installed at the floor in-charge/ matron will be activated. This will help in avoiding any negligence in services.
The system will comprise of
a) Call Station Board,
b) Door Indicator,
c) Digital Display board,
d) Data Logger Card
e) UPS system.
Call Station Board : is consisting of Bed push confirmation light and re-set push. It is designed for standard modular box. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Door Indicator : is consisting of cluster of LEDs mounted in specially designed cabinet. It has Tangle/ Round Red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the Nurses moving by to attend immediately even before going to the Nurses Station. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Call Indicator Board : The Call Indicator Board is to be installed at the Nurse center. Call received from any bed will be displayed by the respective indicator with Green Led against bed number marked | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Digital Display board : The Digital display board is call monitor console which is installed at the Nurse center. All Call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one Nurse Station. It has soft buzzer which alerts the attendment on receipt of any new calls. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Logger Card: This is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thus generated helps the Hospital Management in taking appropriate decisions. The card is supported with specially developed software which is installed in the computer. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
UPS : The system has its own specially designed UPS. It consists of a SMF type 12 v 7 ah battery, automatic battery charger and allied accessories.Unique advantages areLow voltage operation: The incoming mains is converted to 12 V.D.C. in the Power Supply section and patient is not put to danger even due to accidental snatching of wires. Ordering information BPS D20 / D30 Digital Nurses Call Monitoring System.
|
Very simple to install and maintain.
![]() |